Before: When completing a mold change, there was not a short-filled part to compare against to, to verify process settings and press parameters.
After: There is a Transfer parts process in place. Controlled no-pack short-shot study is one of the best methods for validating a transferred or modified mold because it isolates the filling phase from the packing phase.